Surface treatment determines the corrosion resistance, appearance and thread fit of a fastener, and it is tied directly to environmental compliance. When selecting a finish, buyers and engineers must confirm both that mechanical and corrosion performance meet the specification, and that the process complies with discharge regulations and the restricted-substance requirements of the target market. This article outlines the process characteristics, compliance boundaries and selection steps for electroplating, Dacromet-type zinc-aluminum flake coatings and green surface treatments, so that technical and procurement teams use the same basis for discussion.
1. Electroplating: a mature process whose environmental constraints focus on wastewater and exhaust air
Electroplating deposits zinc, zinc alloys, nickel and other metals onto steel fasteners by electrolysis. The most common finishes are zinc plating (white zinc, color/yellow, blue-white) and nickel plating. The coating is uniform and the mating dimensions are controllable, which is why the process is widely used.
The environmental burden of electroplating comes mainly from wastewater and exhaust air. Wastewater carries heavy metals such as chromium, nickel, zinc, cadmium, lead and copper, and some plating processes involve cyanide; exhaust air contains acid mist, chromic acid mist and hydrogen cyanide. China's discharge standard GB 21900-2008 sets limits for hexavalent chromium, total nickel, total cadmium and total lead at the workshop or facility wastewater outlet, and for total zinc and total copper at the final discharge outlet, and it requires local collection and treatment of pollutant-generating equipment. A compliant plating plant must have matching wastewater and exhaust treatment capacity; buyers should verify environmental approval and discharge compliance rather than comparing unit price alone.
Electroplated coatings for fasteners follow ISO 4042:2022 (GB/T 5267.1-2023, modified adoption), which specifies coating systems, internal hydrogen embrittlement requirements and measures to reduce hydrogen risk, and includes the neutral salt spray test (NSS, per GB/T 10125) and the sulfur dioxide test. High-strength steel fasteners of property class 8.8 and above carry a risk of hydrogen uptake during plating; after plating they should be baked to remove hydrogen in line with the standard, to avoid delayed fracture in service.
2. Dacromet and zinc-aluminum flake coatings: non-electrolytic, corrosion-resistant and low in hydrogen embrittlement
The term "Dacromet" on a quotation or drawing first needs its composition clarified. Early Dacromet referred to a zinc-chromate coating containing hexavalent chromium; the current environmentally oriented option is the chromium-free zinc-aluminum flake coating, also called a non-electrolytic zinc flake coating. The two processes are similar, but their composition and environmental profile differ. Technical documents should state whether the coating is zinc-chromate or chromium-free zinc-aluminum, to avoid confusion at acceptance.
The chromium-free zinc-aluminum coating uses a water-based slurry of lamellar zinc and aluminum flakes with a binder. It is applied by dipping, spin-coating or spraying, then baked and sintered into a film, without electrolytic pickling. For fasteners it corresponds to ISO 10683:2018 (GB/T 5267.2-2021, non-electrolytic zinc flake coatings). Corrosion performance is assessed by the neutral salt spray test per GB/T 10125; grades are defined by coating weight and thickness, with time to red rust ranging from 120 to 2000 hours, depending on the grade agreed between supplier and customer.
Because the coating does not involve pickling or electrolysis, the risk of hydrogen embrittlement is low, which suits high-strength fasteners. The lamellar structure gives good barrier protection and penetrates deep holes, narrow slots and tube interiors better than conventional electroplating. The film is typically a few to more than ten micrometers thick, so thread fit allowance must be considered in selection. Its water-based slurry, the absence of electroplating wastewater and cyanide steps, and the chromium-free formulation keep hexavalent chromium out of the finish, making it easier to meet the RoHS Directive (2011/65/EU) and the REACH SVHC list. The sintering step still uses energy and releases small amounts of volatile matter, so it is not a zero-emission process.
3. Green surface treatment: combine options by service conditions and compliance
Green surface treatment is not a single process but a group of low-pollution, low-energy, restricted-substance-compliant and traceable solutions. Chromium-free zinc flake coating, chromium-free passivation, water-based coating, stainless steel passivation (ISO 16048:2003; GB/T 5267.4-2009), black oxide and phosphating are combined according to the application. A pre-applied nylon patch is an anti-loosening treatment and does not change the base corrosion system.
Export orders should be checked against the RoHS and REACH SVHC lists for compliance with restricted substances such as hexavalent chromium, cadmium and lead; domestic projects focus on the supplier's environmental approval, discharge compliance record and accompanying material certificates. A common selection mistake is equating "green" with poorer corrosion resistance or higher cost. In practice, chromium-free zinc flake coatings often outlast ordinary electroplated zinc in harsh environments. The decision should be based on atmospheric category, humidity, contact media and assembly space, then mapped to the relevant standard grade, rather than chosen by process name alone.
4. Steps for procurement and technical alignment
Finish selection should follow the steps below so that technical and procurement teams work from the same basis.
Define the service conditions and operating environment: distinguish indoor dry, outdoor, humid-heavy or corrosive-media exposure, and state the expected service life and required salt spray duration.
Confirm material and property class: for high-strength parts, evaluate low-hydrogen-embrittlement processes first; if electroplating is used, agree on the post-plating hydrogen bake-out.
Select the finish system and standard: state the coating type, whether it contains chromium, the applicable standard, grade or thickness, and the salt spray test duration.
Verify compliance and testing capability: review environmental approval and discharge compliance evidence, RoHS/REACH conformity documentation, and salt spray and hardness test records.
Record the agreement in the technical specification: use sealed samples, material certificates, batch traceability information and accompanying inspection reports as the acceptance basis.
Closing
Kunshan Jinsixi Metalware Co., Ltd. (JINSIXI METALWARE) supplies high-strength bolts, socket screws, assembled screws and custom non-standard fasteners. Finishes are produced to GB, ANSI, DIN, JIS and ISO standards and the relevant fastener finish standards. According to service conditions and export compliance requirements, we can provide zinc plating, nickel plating, black oxide, chromium-free zinc flake coating and pre-applied anti-loosening patch, together with salt spray test records and material certificates. The exact grade, thickness and inspection items are subject to the drawings, samples and technical agreement confirmed by both parties.